Tuesday, October 7, 2008

RS 232 SETTING FOR VARIOUS HEIDEN HAIN (TNC) CONTROLLERS

RS 232 SETTING FOR VARIOUS HEIDEN HAIN (TNC) CONTROLLERS

TNC 355

MP232: 0 (data transfer mode)
MP71: 515 (character for program start and end)
MP222: 104 (data format)

TNC 155
MP232: 0 (data transfer mode)
MP71: 515 (character for program start and end)
MP222: 104 (data format)

TNC 150

MP92: 1(multi function)
MP71: 3(character for program start and end)
Baud rate: 2400

TNC 415 B
DEVICE: EXT 2
MP 5200.1: 2 (External device)
MP 5201.1: 3 (External device)
MP 5020.1: 104
MP 5030.1: 0

TNC 425
DEVICE: EXT 2
MP 5200.1: 2 (External device)
MP 5201.1: 3 (External device)
MP 5020.1: 104
MP 5030.1: 0

TNC 2500
MP 5020: 100(data format)
MP 5030: 0 (standard interface)

TNC 407
DEVICE: EXT 2
MP 5200.1: 2 (External device)
MP 5201.1: 3 (External device)
MP 5020.1: 104
MP 5030.1: 0

HEIDENHEIN CNC PILOT

The following parameter to be set in the parameter #42
To get the parameter #42 follow the following procedure.
Press Parameter -> Configure -> Control direct -> Enter parameter no. 42
Baud rate= 15(19200 baud rate)
Word length= 1(7 Data bits)
Parity= 3(Even)
Stop bits= 0(One)
Protocol= 0(Hardware)